Customization: | Available |
---|---|
Certification: | ISO9001, CCC, CE |
Protection: | IP20 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The working principle of the STD APF series active power filter is to detect the load current in real time, separate the harmonic currents one by one based on the specified harmonic current detection algorithm, and generate and control the driver IGBT output and load harmonic current according to the set filtering percentage. Compensation currents with the same amplitude and opposite phases achieve the purpose of harmonic cancellation.
TYPE
|
Series 220V
|
Series 400V
|
Series 500V
|
Series 690V
|
Max neutral wire current
|
23A
|
15A ,25A ,50A,
75A ,100A ,150A
|
100A
|
100A
|
Nominal voltage
|
AC220V(-20%~+20%)
|
AC380V(-20%~+20%)
|
AC500V(-20%~+20%)
|
AC690V(-20%~+20%)
|
Rated frequency
|
50Hz±5%
|
|||
Network
|
Single phase
|
Three-phase three-wire/three-phase four-wire
|
||
Response time
|
<40ms
|
|||
Harmonics filtering
|
2th to 50th Harmonics,The number of compensation can be selected, and the range of single
compensation can be adjusted
|
|||
Harmonic compensation rate
|
>92%
|
|||
Neutral line filtering capability
|
/
|
The filtering capacity of three-phase four-wire neutral line is 3 times of that
of phase filtering
|
||
machine efficiency
|
>97%
|
|||
Switching frequency
|
32kHz
|
16kHz
|
12.8kHz
|
12 .8kHz
|
Feature selection
|
Deal with harmonics/Deal with harmonics and reactive power
|
Deal with harmonics/Deal with harmonics and reactive power/ Deal with harmonics and three-phase unbalance /Three options
|
||
Numbers in parallel
|
No limitation. A single centralized monitoring module can be equipped with up to 8 power modules
|
|||
Communication methods
|
Two-channel RS485 communication interface (support GPRS/WIFI wireless communication)
|
|||
Altitude without derating
|
<2000m
|
|||
Temperature
|
-20~+50°C
|
|||
Humidity
|
<90% RH,The average monthly minimum temperature is 25ºC without condensation on the surface
|
|||
Pollution level
|
Below level 3
|
|||
Protection function
|
Overload protection, hardware over-current protection, over-voltage protection, power failure
protection, over-temperature protection, frequency anomaly protection, short circuit protection, etc |
|||
Noise
|
<50dB
|
<60dB
|
<65dB
|
|
Installation
|
Rack/wall hanging
|
Rack
|
||
Into the way of line
|
Back entry (rack type), top entry (wall-mounted)
|
Top entry
|
||
Protection grade
|
IP20
|